- TRC-50X Optical Head - Power Supply - One MT-2 Camera back - Chin rest assembly - External fixation device - System is complete and in Excellent working condition - Ideal camera for Digital System Adaptation
$
3,425.00
TOPCON TRC-50 VT Fundus Camera
Description: TOPCON TRC-50VT FUNDUS CAMERA Topcon 50VT is a variable angle retinal camera that has fluorescein angiography capability. The camera has 20,35 and maximum field of 50 deg. The camera automatically compensates photographic illumination as the field size is changed. This camera can be upgraded to a complete digital backend.
$
3,275.00
TOPCON TRC-60 AV/T Fundus Camera
4 angle (60, 40, 30 and 15 degree), F/A and color,includes integrated power table. Only 4mm of Pupil Dilation required at 30 and 15 degree, 5.5mm @ 60 degrees Automatic Exposure System using spot or averaged light measuring Integrated Control Box and auto filtration for fluorescein photography
$
3,650.00
TOPCON KR 8000 Autorefractor
Specifications: Objective Refractometer Mode Sphere -25 to +22D in 0.25D step (0.12D step available) Cylinder 0 to ±8D in step 0.25D (0.12D step available) Axis 1° to 180° in 1° and 5° step Minimal pupil diameter 2.0mm ø Method of relaxation Automatic fogging Charts for object testing Picture Corneal Curvature Mode Corneal curvature radius 5.00mm thru 10.00mm Refraction index 1.3375 Corneal refraction 67.5D thru 33.75D Corneal astigmatism 0D thru ±10D Corneal astigmatism axial angle 1° thru 180° Measuring area 3mm with 7.7mm radius Measuring Step Corneal curvature radius 0.01 mm Corneal refraction 0.12 / 0.25D Corneal astigmatism 0.12 / 0.25D Corneal axis angle 1° / 5° Others PD measurement range 85mm max. in 1 mm step Measuring start Auto Start and Manual Corneal diameter measurement (Pupil diameter) Yes (Range; 2-13mm / Step; 0.25mm) Measurement display TV monitor screen Measurement recording Built-in printer (Up to 10 measurements of each eye can be stored in memory) Alignment Screen display Vertex distance 0, 12.0 and 13.75mm (selectable) Energy saving Automatic switch off when left unused after 10 minutes IOL Special IOL switch to adjust to circumstances of IOL wearers Power supply 100, 120, 220, 240V Output RS-232C Weight 19kg.
$
3,190.00
Topcon KR 3000 autorefactor keratometer
Topcon KR3000 Accomplish full refraction and keratometry measurements for the patient in one fast, simple operation with the Topcon KR3000. The video monitor displays both refraction and keratometry readings simultaneouslyfor immediate comparison. Patients enjoy relaxed, comfortable testing since the KR3000 employs near-infrared light during the measurement process. Touch-switch selection of three different testing modes: refraction, keratometry or both, fast, simple PD measurement. All KR-3000 test functions enjoy exceptional accuracy and reliability.
$
2,050.00
Topcon KR7000 autorefactor keratometer
Combined automatic refractor and keratometer functions in one compact instrument. The omni directional joy-stick and simplified alignment targets ensure ease of operation. Intra-Red light and auto fogging fixation target elimanate discomfort and promote patient compliance. Extensive keratometric reading plus all of the refraction features found in the RMA-7000 searies auto refractor make the KR-7000 one of the most sophisticated diagnostic instruments available.
$
2,650.00
Topcon KR8800 autorefactor keratometer
The KR8800 features fast, easy and accurate measurements, a 20% wider measurement range, a color LCD screen, and a 2.0mm minimum pupil diameter. Fast and accurate refraction and keratometry readings. New color LCD screen. Rotary Prism measurement for enhanced accuracy. 2.0mm minimum pupil diameter. Simultaneous display of binocular readings. Scenic fixation chart. USB connection for fast data transfer. Auto fire mode for fast reliable data collection.
$
3,290.00
Topcon CV-3000 Compu Vision phoroptor
The ALL-NEW CV-3000 Computerized Vision Tester offers the latest features in automated refraction and expands the many features of our complete EXAM-3000 Refraction System. Today's demand for delegating the refraction, electronic data collection, efficiency and ergonomics, continue to generate an incredible interest in this product! The CV-3000 can be mounted on our ALL-NEW EXAM-3000 Delivery Desk or a conventional chair and stand. Find out today how this product can save you time, space and money! Highlights of the new CV-3000 include: - Faster Performance - Integrates with many Topcon Pre-test Instruments - Color Coded Easy Operation - Powered Patient Positioning Features - Proven Performance - Onsite Professional Factory Training - Consistent Accurate Refractions
$
3,250.00
Topcon TRC-NW6S Non-Mydriatic Retinal Camera
The new TRC-NW6S Non-Mydriatic Retinal Camera is the ideal instrument for the growing market in Telemedicine and Diabetic Screening. The camera features eight peripheral fixation points as well as a built-in standard central fixation point, which provide fixed, reproducible fields for use in various study protocols. The main optical system in the TRC-NW6S incorporates a dual magnification mechanism to allow for digital video capture of either 45° or 30° fields. To assist in capturing multiple images using todays advanced video technology, the camera incorporates five flash levels to choose from. This gives the user greater flexibility for capturing all patient images with the most effective level of illumination for each image. The TRC-NW6S is compatible with the Topcon IMAGEnet MOSAIC 2000 software. Once connected to our IMAGEnet system, the fixed field positions are automatically forwarded to the computer so that a composite image may be quickly created in the computer for printout and / or evaluation.
$
5,050.00
TOPCON TRC-50EX Fundus Camera
This tri-functional camera sets the standard for ICG, fluorescein, and color imaging, and is designed with the added flash settings necessary for today’s sensitive digital cameras. A large eyepiece and alignment dots enable the photographer to easily and comfortably align the camera. Superior optical coatings eliminate flare and assure maximum image quality.